Sentinal 233
Liquid-cooled C&I storage cabinet

A 105/125 kW, 233/261 kWh two-hour-class liquid-cooled C&I platform for farms, cold-chain, processing, charging and commercial sites where sustained peaks or solar shifting create measurable value.

Product features

What one cabinet can do

314Ah large-format cells

Liquid cooling thermal management

fire safety

PACK-level + cluster-level (Novec 1230 / aerosol)

anti-corrosion

C5-M corrosion protection (entire series)

−20 ~ 50 °C operating temperature

communication ports

RS485 / CAN

Project fit

A two-hour liquid-cooled cabinet for park peak shaving

Sentinal 233 is a 105 kW / 233 kWh liquid-cooled all-in-one storage cabinet. Selection comes down to power demand, the peak / valley price spread, demand charges, site space and the grid / PCS configuration.

Typical scenarios

One liquid-cooled cabinet covers the main C&I uses

  • Park peak shavingCharge in the valley and discharge at peak to cut peak and demand charges
  • C&I backupKeep critical circuits supplied during an outage and reduce production loss
  • Cabinet-by-cabinet expansionStage budget-sensitive projects; a single cabinet is the smallest unit
  • PV + storage coordinationPair with a PCS to connect PV, smoothing output and raising self-use
  • Remote O&MBuilt-in EMS for centralised dispatch and status monitoring
Request a tailored plan
Core data
0kWRated power
0kWhNominal energy
0%Depth of discharge
0cyclesCycle life @90% DOD

LFP 314 Ah cells · liquid-cooled · built-in EMS · IP54 cabinet

Specifications

Sentinal 233 detailed specifications

Core specifications

Model
Sentinal 233 (liquid-cooled storage cabinet)
Form factor
Liquid-cooled all-in-one storage cabinet (storage only, with PCS)
Rated power / capacity
105 kW / 233 kWh
Depth of discharge
DoD 98%
Cell chemistry
LFP · 314 Ah large cells (common to the series)

Electrical performance

Max efficiency
—
Grid / off-grid transfer
— (storage-only cabinet; determined by the PCS)
Off-grid capability
Off-grid expansion cabinet
PV input
— (storage only; PV connected via PCS)
Communication
RS485 / CAN

Structure & protection

Cooling
Liquid cooling
Ingress protection
IP54 (cabinet)
Fire suppression
PACK-level + cluster-level (Novec 1230 / aerosol)
Corrosion protection
C5-M corrosion protection (entire series)
Operating temperature
−20 ~ 50 °C

Scalability

Cycle life
≥8000 cycles @90% DOD
Multi-cabinet parallel
Cabinet-by-cabinet expansion; multi-cabinet parallel supported

Compliance & certification

Battery / safety
IEC 62619 / 63056
Transport
UN38.3
Grid connection / local
Per the regulations of the project location